[1]周 姣,陈小月.雷击交流侧同塔双回线路时换流站过电压特性[J].电瓷避雷器,2020,(02):162-167.[doi:10.16188/j.isa.1003-8337.2020.02.026]
 ZHOU Jiao,CHEN Xiaoyue.The Overvoltage Characteristics of Converter Station When Lightning Strikes to the Double-Circuit System of 500 kV AC Side[J].,2020,(02):162-167.[doi:10.16188/j.isa.1003-8337.2020.02.026]
点击复制

雷击交流侧同塔双回线路时换流站过电压特性()
分享到:

《电瓷避雷器》[ISSN:1006-6977/CN:61-1281/TN]

卷:
期数:
2020年02期
页码:
162-167
栏目:
避雷器
出版日期:
2020-04-25

文章信息/Info

Title:
The Overvoltage Characteristics of Converter Station When Lightning Strikes to the Double-Circuit System of 500 kV AC Side
作者:
周 姣 陈小月
(1.中国电力科学研究院有限公司武汉分院,武汉 430074; 2.武汉大学电气工程学院,武汉 430072)
Author(s):
ZHOU Jiao CHEN Xiaoyue
(1.China Electric Power Research Institute Wuhan Branch, Wuhan 430072, China; 2.School of Electrical Engineering, Wuhan University, Wuhan 430072, China)
关键词:
同塔双回 换流站 雷电过电压 EMTP/ATP
Keywords:
double-circuit atthe same tower converter station lightning overvoltage EMTP/ATP
DOI:
10.16188/j.isa.1003-8337.2020.02.026
摘要:
超高压电网多采用同塔双回或多回线路,由于杆塔较高,遭受雷击时可能造成多回线路闪络。依托某换流站500 kV交流侧系统,利用EMTP/ATP建立电站雷电侵入波过电压计算模型,研究换流站交流侧同塔双回线路遭受雷击时站内设备上过电压特性以及与单回线路的区别。结果表明:雷击同塔双回线路杆塔时,在两回线路均闪络的情况下,换流站设备上反击侵入波过电压在双线运行方式下幅值远高于单线运行方式,且过电压最大值一般是在雷击进线段第二基杆塔TW2时出现,反击过电压特性与雷击单回线路差异较大; 而同塔双回线路绕击侵入波过电压规律与单回线路类似,单线运行方式下设备过电压高于双线运行方式,且过电压最大值一般出现在雷电绕击距离换流站最近的TW1附近线路。
Abstract:
Double-circuit and multi-circuit lines are widely used in the EHV power grid and may cause multiple line flashovers when lightning strikes to the lines due to the high tower. This paper is based on the 500 kV AC part of a converter station and building the model of computing lightning invasion wave overvoltage of the converter station by means of EMTP/ATP to study the characteristics of lightning overvoltage in the double circuit system and the differences with single circuit system. The results show that, for the double circuit system and in the case where both lines are flashing, the back flashover overvoltage on equipment is much higher in the operation mode with two lines than the operation mode with one line and it generally maximizing when the second tower(TW2)is struck, and the characteristic of back flashover invade overvoltage is obvious different with the single circuit system; The characteristic of shielding failure invade overvoltage on equipment in the double circuit system is similar to the single circuit system, and the overvoltage is higher in the operation mode with one line than the operation mode with two lines and it generally maximizing when the line on the first tower(TW1)is struck owe to the short distance.

参考文献/References:

[1] 潘靖,易辉,陈柏超.我国紧凑型与同塔双回输电现状与展望[J].高电压技术,2005, 09(9):25-27. PAN Jing, YI Hui, CHEN Baichao. Current situation and prospect of compact line and double circuit on sametower in China[J]. High Voltage Engineering, 2005, 09(9): 25-27.
[2] 丁玉剑,李庆峰,廖蔚明,等.同塔双回 ±500 kV直流线路杆塔上层空气间隙放电特性和耐雷性能试验研究[J].中国电机工程学报,2010(28):114-119. DING Yujian, LI Qingfeng, LIAO Weiming, et al. Flashover characteristics of upper air clearances and lightning withstand level for ±500 kV DC double-circuit transmission line towers[J]. Proceedings of the CSEE, 2010(28): 114-119.
[3] 范冕,万磊,戴敏,等.不同串型设计条件下的特高压交流同塔双回线路雷电性能[J].高电压技术,2014, 40(12):3902-3910. FAN Mian, WAN Lei, DAI Min, et al. Lightning performance of UHVAC double-circuit transmission lines on the sametower under different design conditions of insulator string[J]. High Voltage Engineering, 2014, 40(12): 3902-3910.
[4] 鄂盛龙,文习山,蓝磊,等.平原和山区同塔双回特高压输电线路雷击特性模拟试验[J].电网技术,2015(1):118-122. E Chenglong, WEN Xishan, LAN Lei, et al. Scaled model test on lightning stroke performance of UHV double-circuit transmission lines in plain and mountain areas[J]. Power System Technology, 2015, 01(1): 118-122.
[5] 顾悦,张园,李江涛,等.不同电压等级同塔多回线雷电反击性能研究[J].电瓷避雷器,2015(3):138-142. GU Yue, ZHANG Yuan, LI Jiangtao, et al. Study on the lightning back flashover performance of multi-circuit transmission lines with different operating voltages[J]. Insulators and Surge Arresters, 2015(3): 138-142.
[6] 陈冰,徐伟,李志泰.500 kV同塔双回直流输电线路雷电绕击性能的研究[J].电工技术,2009(9):27-29. CHEN Bing, XU Wei, LI Zhitai. Research on lightning shielding of 500 kV double DC circuit on the same tower[J]. Electric Engineering, 2009(9): 27-29.
[7] 王剑,谷山强,赵淳,等.计及工作电压时同塔双回输电线路雷击闪络特性[J].高电压技术,2014, 40(9):2923-2930. WANG Jian, GU Shanqiang, ZHAO Chun, et al. Lightning flashover characteristics of double-circuit transmission line on thesame tower considering working voltage[J]. High Voltage Engineering, 2014, 40(9): 2923-2930.
[8] 蔡雨楠,叶赞.同塔双回输电线路的雷电反击计算及仿真[J].电网与清洁能源,2014(11):57-64. CAI Yunan, YE Zan. Calculation and simulation of lightning back-striking of double circuit transmission lines on the same tower[J]. Advances of Power System & Hydroelectric Engineering, 2014(11): 57-64.
[9] 宋阳,秦颖,胡可.500 kV同塔双回输电线路雷电反击仿真模型的建立与分析[J].电气技术,2012(1):40-42. SONG Yang, QIN Ying, HU Ke.Simulation modeling and analysis of lightning back-striking of 500 kV double circuit transmission line [J]. Electrical Engineering, 2012(1): 40-42.
[10] 李洪涛.500 kV变电站雷电侵入波保护研究[D].重庆:重庆大学,2006.
[11] 中国电力企业联合会.交流电气装置的过电压保护和绝缘配合设计规范:GB/T 50064—2014 [S].北京:中国计划出版社,2014.
[12] 全国高电压试验技术和绝缘配合标准化技术委员会. 绝缘配合 第2部分:使用导则:GB/T 311.2—2013 [S]. 北京:中国电力出版社, 2013.
[13] 鲁铁成.电力系统过电压[M].北京:中国水利水电出版社,2009.
[14] IEEE. Guide for improving the lightning performance of transmission lines:IEEE 1243—1997[S].USA:IEEE,1997.
[15] IEC. Insulation co-ordination part 2:application guide:IEC 60071-2——996 [S].Geneva:IEC,1996.
[16] 衡水衡湖铁塔厂.绝缘子及绝缘子串雷电冲击伏秒特性[EB/OL][2019-12-30]. http://www.zhuangshita.cn/news/32.htm.
[17] 赵贤根,董曼玲,吕金壮,等.同塔双回直流换流站雷电侵入波特性[J].南方电网技术,2013(2):40-44. ZHAO Xiangen, DONG Manling, LV Jinzhuang, et al. The characteristics of lighting intruding overvoltage in the HVDC double circuit system of converter stations[J]. Southern Power SystemTechnology, 2013(2): 40-44.

备注/Memo

备注/Memo:
收稿日期:2019-08-03作者简介:周姣(1991—),女,硕士,工程师,主要从事电力系统过电压与绝缘配合方面的研究工作。